B3 Cables RailwaysB3 Cables RailwaysB3 Cables RailwaysB3 Cables Railways

Trackside Signalling

Typical Cable Applications: Signalling circuits in railway networks

ZPFU (with mechanical protection)
Compliant with French Railway Standards (Société Nationale des Chemins de Fer) SNCF CT 445 & NF C 32-070 Category C2       
1.13 mm plain copper wire with solid Pe insulation, twisted pair, helically stranded cable core, plastic tape core wrap       
Pe inner sheath, 2 x helically applied steel tapes, PVC outer sheath
B3
P/N
No. of Pairs Max DC Cond.
 Resistance
(ohm/km)
Maximum
 Mutual
Capacitance
 (nF/km)
Maximum Cap.
Unbalance
(pF/500 m)
Insulation
Resistance
 (m.ohm/km)
Nominal
Overall
Diameter
(mm)
Nominal
Weight
(kgs/km)
10138998 4 18.1 55 400 5000 16.1 510
10139001 21 18.1 55 400 5000 27.8 1300
Please note: The above cables are available in the range 1 - 56 pairs and with a Low Smoke Zero Halogen Sheath

ZPAU (with induction and electromagnetic protection)
Compliant with French Railway Standards (Société Nationale des Chemins de Fer) SNCF CT 445 & NF C 32-070 Cat C2        
1.13 mm plain copper wire with solid Pe insulation, twisted pair, helically stranded cable core, plastic tape core wrap        
Pe inner sheath, corrugated copper tape, Pe intermediate sheath, 2 x helically applied steel tapes, PVC outer sheath        
B3
P/N
No. of Pairs Max DC Cond.
Resistance
(ohm/km)
Maximum
Mutual
Capacitance
 (nF/km)
Maximum Cap.
Unbalance
(pF/500 m)
Reduction
Factor @ 50Hz
(100V/km)
Nominal
Overall
Diameter
 (mm)
Nominal
Weight
(kgs/km)
10180391 4 18.1 55 400 0.26 20.1 840
10180637 21 18.1 55 400 0.26 31.7 1800
Please note: The above cables are available in the range 4 - 56 pairs and with a Low Smoke Zero Halogen Sheath compliant to NF C 32-070 Category C1

ZC03 (with electrostatic and electromagnetic protection)
Compliant with French Railway Standards (Société Nationale des Chemins de Fer) SNCF CT 445 & NF C 32-070 Cat C2       
1.13 mm plain copper wire with solid Pe insulation, quad construction, helically stranded cable core, plastic tape core wrap       
Pe inner sheath, 2 x helically applied steel tapes, PVC outer sheath       
B3 P/N No. of Quads Max DC Cond.
Resistance (ohm/km)
Maximum
Mutual
Capacitance
 (nF/km)
Maximum Cap.
Unbalance
(pF/500 m)
Reduction
Factor @ 50Hz
 (100V/km)
Nominal
Overall
Diameter
(mm)
Nominal
Weight
 (kgs/km)
10180434 4 18.1 40 400 0.21 27 1300
Please note: The above cable is available with a Low Smoke Zero Halogen Sheath compliant to NF C 32-070 Cat C1

AJ-2Y2YDB2Y  H115/H145 rk 501 Series (with induction and electromagnetic protection)
Compliant with German Railway Standards (Deutsche Bahn) Dlk 1.013.107y & Dlk 1.013.110y Plain copper wire of 0.9, 1.4 or 1.8 mm diameter with solid Pe insulation, helically stranded into concentric layers, plastic tape core wrapPe inner sheath, 1 x layer of helically applied copper wires, 2 x helically applied steel tapes, Pe outer sheath
B3 P/N No. of Cores Conductor
Gauge (mm)
Max DC Cond.
Resistance
(ohm/km)
Maximum
Conductor
Capacitance
 (nF/km)
Reduction
 Factor @ 50Hz
 (100V/km)
Nominal
Overall
Diameter
 (mm)
Nominal
Weight
(kgs/km)
10180638 50 0.9 28.9 115 0.35 22.5 1000
10180639 120 1.4 11.9 145 0.35 36.9 3850
10180640 200 1.8 7.2 145 0.35 55.5 7200
Please note: The above cables are available in the range 10 - 200 cores and without induction protection

A2Y(L)2YV S
Compliant with German Railway Standards (Deutsche Bahn) Dlk 1.013.109y & Dlk 1.013.110y Plain copper wire of 0.9 or 1.4 mm with solid Pe insulation, quad construction, helically stranded cable core, plastic tape core wrap Pe sheath incorporating a longitudinally applied aluminium-copolymer tape with overlap
B3 P/N No. of Quads Conductor
 Gauge (mm)
Max DC Cond.
 Resistance
 (ohm/km)
Maximum
Conductor
Capacitance
 (nF/km)
Insulation
Resistance
 (m.ohm/km)
Nominal
Overall
Diameter
(mm)
Nominal
Weight
(kgs/km)
10180632 5 0.9 28.3 45 10000 15.9 270
10138928 20 1.4 11.7 45 10000 38 1720
Please note: The above cables are available in the range 1 - 40 quads and with reduction protection

15ECWF (with mechanical protection)
Compliant with Spanish Railway Standards (Administrador de Infraestructuras Ferroviarias) ADIF E.T. 03.365.051.6 Plain copper wire of 1.4 mm diameter with solid Pe insulation, helically stranded into concentric layers, plastic tape core wrap Pe inner sheath incorporating a longitudinally applied aluminium-copolymer tape with overlap, 1 x longitudinally applied corrugated steel tape, Pe sheath
B3 P/N No. of Cores Conductor
Gauge (mm)
Nominal
Sheath
Radial (mm)
Max DC Cond.
Resistance
(ohm/km)
Insulation
Resistance
(m.ohm/km)
Nominal
Overall
Diameter
(mm)
Nominal
Weight
(kgs/km)
10138897 12 1.4 1.4 11.9 35000 18.2 450
10180641 100 1.4 1.5 11.9 35000 38.2 2000
Please note: The above cables are available in the range 4 - 100 cores and with reduction protection

15/19EXEF Series 400 (with electrostatic & electromagnetic protection)
Compliant with Spanish Railway Standards (Administrador de Infraestructuras Ferroviarias) ADIF E.T. 03.365.051.6 Plain copper wire of 0.9 or 1.4 mm with solid Pe insulation, quad construction, helically stranded cable core, plastic tape core wrap Pe inner sheath, 1 x helically applied layer of copper wires or one corrugated steel tape, 2 x helically applied steel tapes, Pe sheath 
B3 P/N No. of Quads Conductor
Gauge (mm)
Max DC Cond.
Resistance
(ohm/km)
Maximum
Mutual
Capacitance
 (nF/km)
Insulation
Resistance
 (m.ohm/km)
Nominal
Overall
Diameter
(mm)
Nominal
Weight
 (kgs/km)
10139175 10 0.9 29 45 35000 29.2 1435
10180642 27 1.4 11.7 48 35000 52.3 4000
Please note: The above cables are available in the range 1 - 48 quads and with reduction protection

RT/F3 Axle Counter (with mechanical protection)
Compliant with English Railway Standard (Network Rail) RT/E/PS/00031 & HFFR Cables IEC60332-3 (flammability) & IEC 61034 (smoke emission) Tinned copper wire of 0.9 or 1.4 mm with solid Pe insulation, twisted pair construction, helically stranded cable core, plastic tape core wrap Pe inner sheath incorporating a longitudinally applied aluminium-copolymer tape, corrugated steel tape armour, Halogen Free Flame Retardant (HFFR) sheath
Options: Unfilled, unarmoured, brass tape armour, 3 levels of induction protection 
B3 P/N No. of Pairs Conductor
Gauge (mm)
Max DC Cond.
Resistance
(ohm/km)
Maximum
Mutual
Capacitance
 (nF/km)
Max Average
Attenuation
 @ 1 kHz
(dB/km)
Minimum
Average NEXT @ 1 kHz
 (dB/km)
Nominal
Overall
Diameter (mm)
10139119 2 0.9 30 42 ± 3 0.73 60 22
10180644 10 1.4 12.5 47 ± 3 0.45 60 30.4
Please note: The above cables are available in the range 2 - 24 pairs

XPS & XPZ Axle Counter (with rodent protection)
Compliant with British Railway Standard (Network Rail) NR/L2/SIG/30060, in addition HFFR (XPZ) cables meet BS 6724, IEC 60754, IEC 60332-1 Tinned copper wire of 0.9 or 1.4 mm with solid Pe insulation, twisted pair construction, helically stranded cable core, plastic tape core wrap, woven glass fibre tape, Pe sheath incorporating a longitudinally applied aluminium-copolymer tape applied with overlap
Options: Corrugated steel tape armour, brass tape armour, Halogen Free Flame Retardant (HFFR) sheath 
B3 P/N No. of Pairs Conductor
Gauge (mm)
Max DC Cond.
Resistance
(ohm/km)
Maximum
Mutual
Capacitance
(nF/km)
Max Average
Attenuation
@ 40 kHz
(dB/km)
Characteristic
Impedance 
@ 90 kHz
 (ohms)
Nominal
Overall
Diameter
(mm)
10180606 2 0.9 30 45 2.6 135 ± 10 22
10180595 10 1.4 12.5 50 2.0 135 ± 10 30.4
Please note: The above cables are available in the range 2 - 24 pairs

K23 Metro (with mechanical protection)
Compliant with French Railway Standards (Société Nationale des Chemins de Fer) NF F 55-623 & NF C 32-070 Category C1 Plain copper wire of 0.6, 0.8, 1.0 or 1.2 mm with solid Pe insulation, quad construction, helically or oscillated stranded cable core, plastic tape core wrap Halogen Free Flame Retardant (HFFR) inner sheath incorporating a longitudinally applied aluminium-copolymer tape, 2 x helically applied steel tapes and a Halogen Free Flame Retardant (HFFR) outer sheath 
B3 P/N No. of Pairs Conductor
Gauge (mm)
Minimum Outer
 Sheath Radial
(mm)
Max DC Cond.
Resistance
 (ohm/km)
Insulation
Resistance
 (m.ohm/km)
Nominal
Overall
Diameter (mm)
Nominal
Weight
 (kgs/km)
10180645 8 0.6 1.0 64 5000 16.5 330
10139254 14 0.8 1.4 36 5000 20.5 380
10074425 28 1.0 1.6 23 5000 29.0 940
10074432 14 1.2 1.4 16 5000 25.0 725
Please note: The above cables are available in the range 2 - 896 pairs

Metro DIGICODE-INDOOR (with mechanical protection)
Halogen Free Flame Retardant version compliant with EN 50-266-2-4, IEC 60332-3, EN 50268-2, EN50267 Plain copper wire of 1.4 mm with solid Pe insulation, twin construction, helically stranded cable core, plastic tape core wrap Halogen Free Flame Retardant (HFFR) inner sheath incorporating a longitudinally applied aluminium-copolymer tape, 2 x helically applied steel tapes  and a Halogen Free Flame Retardant (HFFR) outer sheath     
B3 P/N No. of Pairs Conductor
Gauge (mm)
Max DC Cond.
Resistance
 (ohm/km)
Maximum
Mutual Pair
Capacitance (nF/km)
Minimum NEXT 
@ 20.7 KHz
(dB/km)
Minimum FEXT
 @ 20.7 KHz
 (dB/km)
Nominal
Overall
 Diameter (mm)
10180653 1* 0.7 12.1 45 42 48 17.9
10180115 2* 0.7 12.1 45 42 48 19.2
10180646 3 0.7 12.1 45 42 48 20.2
Pair sizes marked with an asterisk (*) have an additional auxilliary pair of 0.6 mm conductor gauge