Dielectric Loose Tube for Blown installation technique
Dielectric strength member, gel filled loose tubes with 12 singlemode fibres per tube (G.652 or G.655), fillers where required for cable geometry, water swellable elements of tapes or yarns, peripherical strength elements of aramid or glass (optional), PE outer sheath.
| E-012-SM2-L12-D-W-P |
12 |
1 |
12 |
9.5 |
114.0 |
| E-024-SM2-L12-D-W-P |
24 |
2 |
12 |
9.5 |
114.0 |
| E-048-SM2-L12-D-W-P |
48 |
4 |
12 |
9.5 |
114.0 |
| E-096-SM2-L12-D-W-P |
96 |
8 |
12 |
11.0 |
132.0 |
| E-144-SM2-L12-D-W-P |
144 |
12 |
12 |
13.6 |
163.2 |
Please note:The above cables are available in the range 12 - 256 fibres
The cables are also available in LS-HFFR version, with an external sheath of Low Smoke Flame Retardant compound: I-012-SM2-L12-D-W-T
The cables have been tested to show compliance with European Norm (EN) 187000, with reference to parts;
501 - Max Tensile Load, 504 - Crush, 513 - Bend, 601 - Temperature Cycling and 605B - Water Penetration
Dielectric Loose Tube for Pulled-in installation technique
Dielectric strength member, gel filled loose tubes with 12 singlemode fibres per tube (G.652 or G.655), fillers where required for cable geometry, water swellable elements of tapes or yarns, peripherical strength elements of aramid or glass, PE outer sheath.
| E-012-SM2-L12-D-W-KP |
12 |
1 |
12 |
12.5 |
187.5 |
| E-024-SM2-L12-D-W-KP |
24 |
2 |
12 |
12.5 |
187.5 |
| E-048-SM2-L12-D-W-KP |
48 |
4 |
12 |
12.5 |
187.5 |
| E-096-SM2-L12-D-W-KP |
96 |
8 |
12 |
17.0 |
255.0 |
| E-144-SM2-L12-D-W-KP |
144 |
12 |
12 |
20.0 |
300.0 |
Please note: The above cables are available in the range 12 - 256 fibres
The cables are also available in LS-HFFR version,
with an external sheath of Low Smoke Flame Retardant compound: I-012-SM2-L12-D-W-KT
The cables are also available in double sheath construction version: E-012-SM2-L12-D-W-PKP
The cables have been tested to show compliance with European Norm (EN) 187000, with reference to parts;
501 - Max Tensile Load, 504 - Crush Values, 513 - Bend, 601 - Temperature Cycling, and 605B - Water Penetration
Dielectric Loose Tube for Short-span aerial installation technique
Dielectric strength member, gel filled loose tubes with 12 singlemode fibres per tube (G.652 or G.655), fillers where required for cable geometry, water swellable elements of tapes or yarns, PE inner sheath, peripherical strength elements of aramid or glass, PE outer sheath.
| A-012-SM2-L12-D-W-PKP |
12 |
1 |
12 |
14.5 |
217.5 |
| A-024-SM2-L12-D-W-PKP |
24 |
2 |
12 |
14.5 |
187.5 |
| A-048-SM2-L12-D-W-PKP |
48 |
4 |
12 |
14.5 |
187.5 |
| A-096-SM2-L12-D-W-PKP |
96 |
8 |
12 |
19.0 |
255.0 |
| A-144-SM2-L12-D-W-PKP |
144 |
12 |
12 |
22.0 |
300.0 |
Please note: The above cables are available in the range 12 - 256 fibres
The cables have been tested to show compliance with European Norm (EN) 187000, with reference to parts;
501 - Max Tensile Load, 504 - Crush Values, 513 - Bend, 601 - Temperature Cycling, and 605B - Water Penetration
Monotube Dielectric Cable for Drop applications
Dielectric strength member, gel filled loose tube with up to 24 fibres (G.652 or G.657), or multimode fibres (G.651 - OM1, OM2 or OM3), water swellable elements of tapes or yarns, peripherical strength elements of aramid or glass, PE outer sheath.
| E-012-SM2-C12-D-W-EP |
12 |
1 |
12 |
7.2 |
72.0 |
| E-012-SM7-C12-D-W-EP |
12 |
1 |
12 |
7.2 |
72.0 |
| E-012-OM1-C12-D-W-EP |
12 |
1 |
12 |
7.2 |
72.0 |
| E-012-OM2-C12-D-W-EP |
12 |
1 |
12 |
7.2 |
72.0 |
| E-012-OM3-C12-D-W-EP |
12 |
1 |
12 |
7.2 |
72.0 |
Please note: The cables are also available in LS-HFFR version,
with an external sheath of Low Smoke Flame Retardant compound: I-012-SM2-C12-D-W-ET
The cables have been tested to show compliance with European Norm (EN) 187000, with reference to parts;
501 - Max Tensile Load, 504 - Crush Values, 513 - Bend, 601 - Temperature Cycling, and 605B - Water Penetration